POWER SUPPLY
Input: 20 to 60, 90 to 180 VDC in two optional modules
Led Indicator power out.
Protection Input fuse, Current Limit, Short circuit
HFD IEC255-22-1 Cl 11.
Impulse IEC255-5 Cl 111
PSU Burden 3 watts max (1.5 typical) per PSU
FO Burden 5 watts max (3.5 typical) per FO Interface
GENERAL
Isolation: 500 VDC between-:
1/ Data Signals and PSU earth.
2/ I/P & O/P Data signals and earth.
Temp. Operating: -5°C to 50°C.
Temp. Storage: -20°C to +85°C.
Relative Humidity: 5% to 95% at +40°C.
non condensing.
Altitude: 0 to 3000 Meters
MECHANICAL
Case: 19" standard rack width x 1U high.
Overall size: 482.6mm x 43.6mm x 160mm depth.
|
FIBRE OPTIC INTERFACE
Multimode
Receiver: ST, 62.5/125 um fibre cable
Transmitter: ST, 62.5/125 um fibre cable
Wavelength: 810 to 890 nm
Optical Att: 12dB max.Transmitter to Receiver.
Up to 2 kms depending on cable quality
Singlemode
Receiver: ST, 9/125 um fibre cable
Transmitter: ST, 9/125 um fibre cable
Wavelength: 1265 to 1380 nm
Optical Att: 12dB max.Transmitter to Receiver.
Up to 20 kms depending on cable quality
G703 ELECTRICAL CONNECTION
Co-Directional: G703, 64KBit
Termination: 120 ohm
Response delay: < 500nSec
Led Indicators: Data Signal present. Rx & Tx.
Power.
|